+ Kyotto ++
Kyotto SSR's have the folling advatageous features:
- High Reliability, Long Life
- Safety
- Low Input Power Consumption
- No Contact Points
- No Switching Sparks
- No Noise
- No Mechanical Damage
- Needs No Maintenance
- Needs no Mechanical Motion, Electronic Devices
- Fast Reaction, Fits in High Frequency Motions
- Zero-Cross and Random Switching Options
MODEL NUMBER DESCRIPTIONS
KYOTO's model numbers of SSR show special implication. The users can easily choose what they want from reading the model number. The following is the unified example to help users read the model number.


Solid State Relay (SSR) KA Series(DC - AC)
|
Solid State Relay (SSR) KB Series(DC - AC)
KB20(DC - AC)(280VAC)
KB40(DC - AC)(480VAC)
|

Solid State Relay (SSR) KD Series(DC - AC)
KD20(DC - AC)(280VAC)
KD40(DC - AC)(480VAC)
|
Solid State Relay (SSR) KE Series(DC - DC)
|
Solid State Relay (SSR) KF Series(DC - DC)
|
Solid State Relay (SSR) KG Series(DC - DC)
KG10(DC - DC)(140VDC)
KG20(DC - DC)(300VDC)
|

Solid State Relay (SSR) KL Series(AC - AC)
KL20(AC - AC)(280VAC)
KL40(AC - AC)(480VAC)
|

Solid State Relay (SSR) KM Series(AC - AC)
|

Solid State Relay (SSR) KN Series(AC - DC)
|

Solid State Relay (SSR) KR Series(VR - AC)
KR20(VR - AC)(280VAC)
KR40(VR - AC)(480VAC)
|

Solid State Relay (SSR) IO-X-20C04A Series(DC - AC)(1/2/4/8 Port)
|

Solid State Relay (SSR) IO-X-0604D Series(DC - DC)(1/2/4/8 Port)
|

Solid State Relay (SSR) 3 PHASE (HEATER LOAD) Series
K3PH20C**AA(AC-AC)(280VAC)
K3PH40C**AA(AC-AC)(480VAC)
K3PH20C**DA(DC-AC)(280VAC)
K3PH40C**DA(DC-AC)(480VAC)
|

Solid State Relay (SSR) 3 PHASE (INUCTIVE LOAD) Series
K3PI20**AA(AC-AC)(280VAC)
K3PI40**AA(AC-AC)(480VAC)
K3PI20**DA(DC-AC)(280VAC)
K3PI40**DA(DC-AC)(480VAC)
|

Solid State Relay (SSR) 2 PHASE (HEATER LOAD) Series
|

Accessories (HEAT SINK) Series
|

Solid State Relay (SSR) KC Series(CURRENT- ACV)
KC20(CURRENT - ACV)(280VAC)
KC40(CURRENT - ACV)(480VAC)
|

Solid State Relay (SSR) KS Series(Mini TYPE)
|
|
|
|
Solid State Relay (SSR) KA Series(DC - AC)(280VAC)
|
AC SOLD STATE RELAY
|
KA 20C02A
|
KA 20C04A
|
KA SERIES
|
|
|
|
SPECIFICATIONS |
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KA 20C02A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
2A
|
24-280VAC
|
600VAC
|
LESS 3 mA
|
47-70HZ
|
30A
|
KA20C04A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-280VAC
|
600VAC
|
LESS 3 mA
|
47-70HZ
|
30A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KA20C02A
|
100 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
15 g
|
KA20C04A
|
100 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
15 g
|
|
OUTLINE DIMENSIONS |
 |
|
 |
|
CHARACTERISTIC CURVES |
 |
Attention: |
|
In order be in compliance with the EMC directive an additional X2 capacitor at the output is requried if the SSR is operated as single component.
In case the SSR is EMI fitter may provide the required EMI suppersion.
the X2 capacitor must be placed as close as possible to the output temminate see also above. |
|
 |
 |
|
 |
|
|
|
|
|
Top
|
Solid State Relay (SSR) KB Series(DC - AC)
|
|
|
KB20(DC - AC)(280VAC)
|
AC SOLID STATE RELAY
|
KB20C02A
|
KB20C03A
|
KB20C04A
|
KB20C06A
|
KB SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KB20C02A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
2A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
30A
|
KB20C02A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
3A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
40A
|
KB20C04A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
50A
|
KB20C06A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
6A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
60A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KB20C02A
|
100 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
10 g
|
KB20C03A
|
100 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
KB20C04A
|
100 V/£gSEC
|
2.0VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
KB20C06A
|
200 V/£gSEC
|
2.0VAC
|
109 ohm
|
4000 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
CHARACTERISTIC CURVES |
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
KB40(DC - AC)(480VAC)
|
AC SOLID STATE RELAY
|
KB40C04A
|
KB40C06A
|
KB SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KB40C04A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-480VAC
|
1200VAC
|
LESS 5 mA
|
47-70HZ
|
50A
|
KB40C06A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
6A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
60A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KB40C04A
|
500 V/£gSEC
|
2.0VAC
|
109 ohm
|
2500 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
KB20C06A
|
500 V/£gSEC
|
2.0VAC
|
109 ohm
|
2500 VACrms
|
____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
CHARACTERISTIC CURVES |
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
Solid State Relay (SSR) KC Series(CURRENT- ACV)
|
|
|
KC20(CURRENT - ACV)(280VAC)
|
CURRENT CONTROL S.S.R
|
KC2010AX
|
KC2015AX
|
KC2025AX
|
KC2040AX
|
KC2050AX
|
KC2075AX
|
KC2090AX
|
KC SERIES
|
|
|
|
Product Description |
The analog switching relay works in accordance with the phase angle control principle, i.e. the output switching point in the AC sine wave depends on the control current. 4mA corresponds to no switching and 20mA corresponds to full sine wave (near line-ar power response). The relay switches off every time the output current crosses zero, and switches ON in accordance with the
applied control current |
SPECIFICATIONS |
|
MODEL NO. |
Current Control |
Max Load Current |
Rated Operational
Voltage |
Non-rep. peak
Voltage |
Insulation Voltage
Input-Output |
Insulation Voltage
Output-Case |
KC2010AX
|
4~20mA
( DC3.8~10V )
|
10A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2015AX
|
4~20mA
( DC3.8~10V )
|
15A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2025AX
|
4~20mA
( DC3.8~10V )
|
25A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2040AX
|
4~20mA
( DC3.8~10V )
|
40A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2050AX
|
4~20mA
( DC3.8~10V )
|
50A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2075AX
|
4~20mA
( DC3.8~10V )
|
75A
|
24~280VAC
|
600V peak
|
4000Vrms
|
2500Vrms
|
KC2090AX
|
4~20mA
( DC3.8~10V )
|
90A
|
24~280VAC
|
1200V peak |
4000Vrms
|
2500Vrms
|
|
|
MODEL NO. |
Operational
Frequency Range |
Power Factor |
Operating
Temperature |
Storage
Temperature |
Junction Temperature |
Weight (g) |
CE-marking |
KC2010AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2015AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2025AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2040AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2050AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2075AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC2090AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
|
|
Output Specifications |
|
Mini Operational
Current |
Rep. overload
Current t=1s |
Non-rep. Surge
Current t=10ms |
Off-state leakage
Current |
I2t for fusing
t=1 - 10 ms |
Critical dl/dt
@50hz |
Critical dV/dt
off-state min. |
10A
|
150mA
|
25Ap
|
120Ap
|
<4mA
|
60A2s
|
100A/ µ
|
1000V/µ
|
15A
|
150mA
|
25Ap
|
168Ap
|
<4mA
|
180A2s
|
100A/ µ
|
1000V/µ
|
25A
|
150mA
|
25Ap
|
300Ap
|
<4mA
|
400A2s
|
100A/ µ
|
1000V/µ
|
40A
|
150mA
|
25Ap
|
420Ap
|
<4mA
|
1250A2s
|
100A/ µ
|
1000V/µ
|
50A
|
150mA
|
25Ap
|
520Ap
|
<4mA
|
1300A2s
|
100A/µ
|
1000V/µ
|
75A
|
150mA
|
25Ap
|
750Ap
|
<4mA
|
1800A2s
|
100A/ µ
|
1000V/µ
|
90A
|
150mA
|
25Ap
|
1400Ap
|
<4mA
|
7200A2s
|
100A/ µ
|
1000V/µ
|
|
|
Input Specifications |
|
Control current
Range |
Pick up Current |
Drop out Current |
Response time
(Input - Output ) |
Off-state leakage
Current |
Dynamic
Impedance |
Allowable input
Current (max.) |
Reverse Polarity
Protected |
4~20mA
|
4mA
|
3.5mA
|
10ms
|
>10VDC @20mA
|
150
|
50mA
|
Yes
|
|
|
|
KC40(CURRENT - ACV)(480VAC)
|
CURRENT CONTROL S.S.R
|
KC4010AX
|
KC4015AX
|
KC4025AX
|
KC4040AX
|
KC4050AX
|
KC4075AX
|
KC4090AX
|
KC SERIES
|
|
|
|
Product Description |
The analog switching relay works in accordance with the phase angle control principle, i.e. the output switching point in the AC sine wave depends on the control current. 4mA corresponds to no switching and 20mA corresponds to full sine wave (near line-ar power response). The relay switches off every time the output current crosses zero, and switches ON in accordance with the
applied control current |
SPECIFICATIONS |
|
KC4010AX
|
4~20mA
( DC3.8~10V )
|
10A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4015AX
|
4~20mA
( DC3.8~10V )
|
15A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4025AX
|
4~20mA
( DC3.8~10V )
|
25A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4040AX
|
4~20mA
( DC3.8~10V )
|
40A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4050AX
|
4~20mA
( DC3.8~10V )
|
50A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4075AX
|
4~20mA
( DC3.8~10V )
|
75A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
KC4090AX
|
4~20mA
( DC3.8~10V )
|
90A
|
48~480VAC
|
1200V peak
|
4000Vrms
|
2500Vrms
|
|
|
MODEL NO. |
Operational
Frequency Range |
Power Factor |
Operating
Temperature |
Storage
Temperature |
Junction Temperature |
Weight (g) |
CE-marking |
KC4010AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4015AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4025AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4040AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4050AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4075AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
KC4090AX
|
40 to 65 Hz
|
>0.90
|
0° to +70c °
|
-20c° to +100c°
|
125c °
|
Approx.
100g
|
Yes
|
|
|
Output Specifications |
|
Mini Operational
Current |
Rep. overload
Current t=1s |
Non-rep. Surge
Current t=10ms |
Off-state leakage
Current |
I2t for fusing
t=1 - 10 ms |
Critical dl/dt
@50hz |
Critical dV/dt
off-state min. |
10A
|
150mA
|
25Ap
|
120Ap
|
<4mA
|
60A2s
|
100A/ µ
|
1000V/µ
|
15A
|
150mA
|
25Ap
|
168Ap
|
<4mA
|
180A2s
|
100A/ µ
|
1000V/µ
|
25A
|
150mA
|
25Ap
|
300Ap
|
<4mA
|
400A2s
|
100A/ µ
|
1000V/µ
|
40A
|
150mA
|
25Ap
|
420Ap
|
<4mA
|
1250A2s
|
100A/ µ
|
1000V/µ
|
50A
|
150mA
|
25Ap
|
520Ap
|
<4mA
|
1300A2s
|
100A/µ
|
1000V/µ
|
75A
|
150mA
|
25Ap
|
750Ap
|
<4mA
|
1800A2s
|
100A/ µ
|
1000V/µ
|
90A
|
150mA
|
25Ap
|
1400Ap
|
<4mA
|
7200A2s
|
100A/ µ
|
1000V/µ
|
|
|
Input Specifications |
|
Control current
Range |
Pick up Current |
Drop out Current |
Response time
(Input - Output ) |
Off-state leakage
Current |
Dynamic
Impedance |
Allowable input
Current (max.) |
Reverse Polarity
Protected |
4~20mA
|
4mA
|
3.5mA
|
10ms
|
>10VDC @20mA
|
150
|
50mA
|
Yes
|
|
|
|
Solid State Relay (SSR) KD Series(DC - AC)
|
|
|
KD20(DC - AC)(280VAC)
|
AC SOLID STATE RELAY
|
KD20C10AX
|
KD20C15AX
|
KD20C25AX
|
KD20C40AX
|
KD20C50AX
|
KD20C75AX
|
KD20C90AX
|
KD20C100AX
|
KD SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KD20C10AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
10A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
100A
|
KD20C15AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
15A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
160A
|
KD20C25AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
25A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
260A
|
KD20C40AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
40A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
400A
|
KD20C50AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
50A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
625A
|
KD20C75AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
75A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
1000A
|
KD20C90AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
90A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
|
KD20C100AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
110A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47-70HZ
|
1200A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KD20C10AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KD20C15AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KD20C25AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD20C40AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD20C50AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD20C75AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD20C90AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD20C100AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
|
|
KD40(DC - AC)(480VAC)
|
AC SOLID STATE RELAY
|
KD40C10AX
|
KD40C15AX
|
KD40C25AX
|
KD40C40AX
|
KD40C50AX
|
KD40C75AX
|
KD40C90AX
|
KD40C100AX
|
KD SERIES HIGH CURRENT
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KD40C10AX
|
4 TO 32 VDC |
MAX 1.0 VDC |
1.5 Kohm |
10A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47-70HZ
|
260A
|
KD40C15AX
|
4 TO 32 VDC |
MAX 1.0 VDC |
1.5 Kohm |
15A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47-70HZ
|
260A
|
KD40C25AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
25A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47-70HZ
|
260A
|
KD40C40AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
40A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47-70HZ
|
400A
|
KD40C50AX
|
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
50A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47-70HZ
|
625A
|
KD40C75AX |
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
75A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47~70HZ
|
1000A
|
KD40C90AX |
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
90A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47~70HZ
|
|
KD40C100AX |
4 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
100A
|
48-480VAC
|
1200VAC
|
LESS15mA
|
47~70HZ
|
1200A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KD40C10AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KD40C15AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KD40C25AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KD40C40AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KD40C50AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrm
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD40C75AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD40C90AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KD40C100AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
|
|
Solid State Relay (SSR) KE Series(DC - DC)
|
|
AC SOLID STATE RELAY
|
KE0602D
|
KE0604D
|
KE SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KE0602D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
2 A
|
3-60 VDC
|
80VDC
|
LESS1 mA
|
47~70HZ
|
3 A
|
KE0604D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4 A
|
3-60 VDC
|
80VDC
|
LESS1 mA
|
47~70HZ
|
8.5 A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KE0602D
|
200 V/£gSEC
|
1.2 VACrms
|
109 ohm
|
2500 VACrm
|
_____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
15 g
|
KE0604
|
200 V/£gSEC
|
1.2 VACrms
|
109 ohm
|
2500 VACrm
|
_____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
15 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KF Series(DC - DC)
|
|
AC SOLID STATE RELAY
|
KF0602D
|
KF0604D
|
KF SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KF0602D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
2 A
|
3-60 VDC
|
80VDC
|
LESS1 mA
|
47~70HZ
|
3 A
|
KF0604D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4 A
|
3-60 VDC
|
80VDC
|
LESS1 mA
|
47~70HZ
|
8.5 A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KF0602D
|
200 V/£gSEC
|
1.2 VACrms
|
109 ohm
|
2500 VACrm
|
_____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
10 g
|
KF0604D
|
200 V/£gSEC
|
1.2 VACrms
|
109 ohm
|
2500 VACrm
|
_____
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KG Series(DC - DC)
|
|
|
KG10(DC - DC)(140VDC)
|
AC SOLID STATE RELAY
|
KG1005D
|
KG1010D
|
KG1025D
|
KG1040D
|
KG1050D
|
KG1075D
|
KG SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KG1005D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
10 A
|
5-120VDC
|
120VDC
|
LESS 3 mA
|
47~70HZ
|
6A
|
KG1010D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
15 A
|
5-120VDC
|
120VDC
|
LESS 5 mA
|
47~70HZ
|
15A
|
KG1025D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
25 A
|
5-120VDC
|
120VDC
|
LESS 7 mA
|
47-70HZ
|
35A
|
KG1040D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
40 A
|
5-120VDC
|
120VDC
|
LESS 7 mA
|
47-70HZ
|
52A
|
KG1050D
|
3 TO 32 VDC
|
MAX 1.0 VDC |
1.5 Kohm |
50 A
|
5-120VDC
|
120VDC
|
LESS 7 mA
|
47-70HZ
|
150 A
|
KG1075D
|
3 TO 32 VDC
|
MAX 1.0 VDC |
1.5 Kohm |
75 A
|
5-120VDC
|
120VDC
|
LESS 7 mA
|
47-70HZ
|
225A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KG1005D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG1010D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG1025D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG1040D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG1050D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE |
LESS 15 PF
|
95 g
|
KG1075D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE |
LESS 15 PF
|
95 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
KG20(DC - DC)(300VDC)
|
AC SOLID STATE RELAY
|
KG2010D
|
KG2025D
|
KG2040D
|
KG2050D
|
KG2075D
|
KG SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KG2010D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
10 A
|
5-220VDC
|
240VDC
|
LESS 3 mA
|
47~70HZ
|
15A
|
KG2025D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
25A
|
5-220VDC
|
240VDC
|
LESS 5 mA
|
47~70HZ
|
35A
|
KG2040D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
40A
|
5-220VDC
|
240VDC
|
LESS 7 mA
|
47-70HZ
|
52A
|
KG2050D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
50A
|
5-220VDC
|
240VDC
|
LESS 7 mA
|
47-70HZ
|
150A
|
KG2075D
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
75A
|
5-220VDC
|
240VDC
|
LESS 7 mA
|
47-70HZ
|
225A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KG2010D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG2025D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG2040D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG2050D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KG2075D
|
200 V/£gSEC
|
2.0Vrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE |
LESS 15 PF
|
95 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
|
|
Solid State Relay (SSR) KL Series(AC - AC)
|
|
|
KL20(AC - AC)(280VAC)
|
AC SOLID STATE RELAY
|
KL20C10AX
|
KL20C15AX
|
KL20C25AX
|
KL20C40AX
|
KL20C50AX
|
KL20C75AX
|
KL20C100AX
|
KL SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KL20C10AX
|
80 TO 280 VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
10 A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
100 A
|
KL20C15AX
|
80 TO 280 VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
15 A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
160 A
|
KL20C25AX
|
80 TO 280 VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
25 A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
260 A
|
KL20C40AX
|
80 TO 280 VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
40 A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
400 A
|
KL20C50AX
|
80TO 280VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
50A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47~70HZ
|
625A
|
KL20C75AX
|
80TO 280VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
75A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47~70HZ
|
1000A
|
KL20C100AX
|
80TO 280VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
100A
|
24-280VAC
|
600VAC
|
LESS 7.5 mA
|
47~70HZ
|
1200A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KL20C10AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KL20C15AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
KL20C25AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KL20C40AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KL20C50AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KL20C75AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
KL20C100AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VAC (rms)
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
KL40(AC - AC)(480VAC)
|
AC SOLID STATE RELAY
|
KL40C25AX
|
KL40C40AX
|
KL40C50AX
|
KL40C75AX
|
L40C100AX
|
KL SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KL40C25AX
|
80-280VAC
|
MAX10VAC
|
1.5 Kohm
|
25A
|
48~480VAC
|
1200VAC
|
15mA
|
47-70HZ
|
260A
|
KL40C40AX
|
80-280VAC
|
MAX10VAC
|
1.5 Kohm
|
40A
|
48~480VAC
|
1200VAC
|
15mA
|
47~70HZ
|
400A
|
KL40C50AX
|
80-280VAC
|
MAX10VAC
|
1.5 Kohm
|
50A
|
48~480VAC
|
1200VAC
|
15mA
|
47-70HZ
|
625A
|
.KL40C75AX |
80-280VAC
|
MAX10VAC
|
1.5Kohm
|
75A
|
48~480VAC
|
1200VAC
|
15mA
|
47-70HZ
|
1000A
|
KL40C100AX |
80-280VAC
|
MAX10VAC
|
1.5Kohm
|
100A
|
48~480VAC
|
1200VAC
|
15mA
|
47-70HZ
|
1200A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KL40C25AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
100 g
|
KL40C40AX
|
200 V/£gSEC
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
KL40C50AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec |
LESS 1/2 AC CYCLE |
LESS 15 PF
|
100 g
|
KL40C75AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec |
LESS 1/2 AC CYCLE |
LESS 15 PF
|
100 g
|
KL40C100AX |
200 V/£gSEC |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec |
LESS 1/2 AC CYCLE |
LESS 15 PF
|
100 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KM Series(AC - AC)
|
AC SOLID STATE RELAY
|
KM20C02A
|
KM20C04A
|
KM20C06A
|
KM SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KM20C02A
|
80 TO 280 VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
2A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
30A
|
KM20C04A
|
80TO 280VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
50A
|
KM20C06A
|
80TO 280VAC
|
MAX 1.0 VDC
|
1.5 Kohm
|
6A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
60A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KM20C02A
|
100 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
______
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
10 g
|
KM20C04A
|
100 V/£gSEC
|
2.0VAC
|
109 ohm
|
4000 VACrms
|
______
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
KM20C06A
|
100 V/£gSEC
|
2.0VAC
|
109 ohm
|
4000 VACrms
|
______
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KN Series(AC - DC)
|
AC SOLID STATE RELAY
|
KN0602D
|
KN0604D
|
KN SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL VOLTAGE
RANGE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KN0602D
|
80~280VAC
|
MAX10VAC
|
1.5 Kohm
|
2A
|
3-60VDC
|
80VDC
|
LESS 1 mA
|
47~70HZ
|
3A
|
KN0604D
|
80~280VAC
|
MAX10VAC
|
1.5 Kohm
|
4A
|
3-60VDC
|
80VDC
|
LESS 1 mA
|
47~70HZ
|
8.5A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KN0602D
|
200 V/£gSEC
|
1.2Vrms
|
109 ohm
|
2500Vrms
|
______
|
LESS 2 mSec
|
LEES1/2 See
|
LESS 15 PF
|
10 g
|
KN0604D
|
200 V/£gSEC
|
1.2Vrms
|
109 ohm
|
2500Vrms
|
______
|
LESS 2 mSec
|
LEES1/2 See
|
LESS 15 PF
|
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KR Series(VR - AC)
|
|
|
KR20(VR - AC)(280VAC)
|
AC SOLID STATE RELAY
|
KR2010AX
|
KR2015AX
|
KR2025AX
|
KR2040AX
|
KR SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL
IMPEDANCE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KR2010AX
|
VR0~500K£[
|
MAX10VAC
|
1.5 Kohm
|
10A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
100A
|
KR2015AX
|
VR0~500K£[
|
MAX10 VAC
|
1.5 Kohm
|
15A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47~70HZ
|
160A
|
KR2025AX
|
VR0~500K£[ |
MAX10 VAC
|
1.5 Kohm
|
25A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
260A
|
KR2040AX
|
VR0~500K£[ |
MAX10 VAC
|
1.5 Kohm
|
40A
|
24-280VAC
|
600VAC
|
LESS 5 mA
|
47-70HZ
|
400A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KR2010AX
|
200V¡þ£gsec
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
92 g
|
KR2015AX
|
200V¡þ£gsec
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
KR2025AX
|
200V¡þ£gsec |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE |
LESS 15 PF
|
95 g
|
KR2040AX
|
200V¡þ£gsec |
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE |
LESS 15 PF
|
95 g
|
|
|
OUTLINE DIMENSIONS |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
KR40(VR - AC)(480VAC)
|
AC SOLID STATE RELAY
|
KR4025AX
|
KR4040AX
|
KR SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL
IMPEDANCE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
KR4025AX
|
VR 0~1M K£[
|
MAX10VAC
|
1.5 Kohm
|
25A
|
48~480VAC
|
1200VAC
|
15mA
|
47~70HZ
|
260A
|
KR4040AX
|
VR 0~1M K£[
|
MAX10 VAC
|
1.5 Kohm
|
40A
|
48~480VAC
|
1200VAC
|
15mA
|
47~70HZ
|
400A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
KR4025AX
|
200V¡þ£gsec
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
95 g
|
KR4040AX
|
200V¡þ£gsec
|
2.0VACrms
|
109 ohm
|
4000 VACrms
|
2500 VACrms
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
|
|
|
OUTLINE DIMENSIONS(unit:mm) |
 |
|
EQUIVALENT CIRCUIT |
 |
|
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
 |
|
 |
|
|
|
|
|
|
|
Solid State Relay (SSR) KS Series(Mini TYPE)
|
|
AC SOLID STATE RELAY
|
KS2002A DC—AC
|
KS4002A DC—AC
|
KS0602D DC—DC
|
KS SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL NO. |
CONTROL
IMPEDANCE |
MUST TURN
OFF VOLTAGE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
SWITCHING TYPE |
KS2002A DC-AC
|
3-32 VDC
|
1 VDC
|
2 A
|
24-280VAC
|
600 PEAK
|
ZEAO CROSS
|
KS4002A DC-AC
|
3-32 VDC
|
1 VDC
|
2 A
|
48-480VAC
|
12000 PEAK
|
ZEAO CROSS
|
KS0602D DC-DC
|
3-32 VDC
|
1 VDC
|
2 A
|
3-60VDC
|
80VDC
|
N/A
|
|
|
|
|
Solid State Relay (SSR) IO-X-20C04A Series(DC - AC)(1/2/4/8 Port)
|
AC SOLID STATE RELAY
|
IO-X-20C04A
|
|
IO-X-40C04A
|
|
(HEATEA LOAD ONLY)
|
IO SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL
IMPEDANCE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
IO-X-20C04A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-280VAC
|
280VAC
|
LESS 5 mA
|
47-70HZ
|
50A
|
IO-X-40C04A
|
3 TO 32 VDC
|
MAX 1.0 VDC
|
1.5 Kohm
|
4A
|
24-280VAC
|
280VAC
|
LESS 5 mA
|
47~63 HZ
|
50A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
IO-X-20C04A
|
100 V/£gSEC
|
1.5VAC
|
|
4000 VACrms
|
_______
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
IO-X-40C04A
|
500 V/£gSEC
|
1.5VAC
|
109 ohm
|
4000 VACrms
|
_______
|
LESS 2 mSec
|
LESS 1/2 AC CYCLE
|
LESS 15 PF
|
12 g
|
|
|
PS: X= 1PORT / 2PORT / 4PORT / 8PORT |
|
OUTLINE DIMENSIONS(unit:mm) |
Model
|
Dimension
(LxWxH)mm
|
IO-2-20C04A
IO-2-40C04A
|
34x85x51
|
IO-4-20C04A
IO-4-40C04A
|
64x85x51
|
IO-8-20C04A
IO-8-40C04A
|
124x85x51
|
|
 |
|
EQUIVALENT CIRCUIT |
 |
|
CHARACTERISTIC CURVES |
 |
Attention: |
|
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the
output is requried if the SSR is operated as
single component. In case the SSR is
incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
|
temminats. See also above. |
|
 |
|
|
|
 |
|
 |
|
|
|
|
Solid State Relay (SSR) 3 PHASE (HEATER LOAD) Series
|
|
|
|
K3PH20C**AA(AC-AC)(280VAC)
|
AC SOLID STATE RELAY
|
K3PH20C25AA
|
K3PH20C40AA
|
K3PH20C50AA
|
K3PH20C75AA
|
K3PH20C100AA
|
(HEATEA LOAD ONLY)
|
3PHASE SERIES
|
|
|
|
SPECIFICATIONS |
|
MODEL
NO. |
CONTROL
IMPEDANCE |
MUST TURN
OFF VOLTAGE |
INPUT
IMPEDANCE |
MAX LOAD
CURRENT |
LOAD VOLTAGE
RANGE |
MIN BLOCKING
VOLTAGE |
MAX OFF-STATE
LEAKAGE |
FREQUENCY
RANGE |
MAX 1-CYCLE
PEAK SURGE |
K3PH20C25AA
|
80 ~280VAC
|
MAX 3VDC
|
1.5 Kohm
|
25A
|
24-280VAC
|
600VAC
|
LESS 10 mA
|
47-63HZ
|
315A
|
K3PH20C40AA |
80 ~280VAC
|
MAX 3VDC
|
1.5Kohm
|
40A
|
24-280VAC
|
600VAC
|
LESS 10 mA
|
47-63HZ
|
450A
|
K3PH20C50AA |
80 ~280VAC
|
MAX 3VDC
|
|
50A
|
24-280VAC
|
600VAC
|
LESS 10 mA
|
47-63HZ
|
560A
|
K3PH20C75AA
|
80 ~280VAC
|
MAX 3VDC
|
1.5 Kohm
|
75A
|
24-280VAC
|
600VAC
|
LESS 10 mA
|
47-63HZ
|
750A
|
K3PH20C100AA
|
80 ~280VAC
|
MAX 3VDC
|
1.5Kohm
|
100A
|
24-280VAC
|
600VAC
|
LESS 10 mA
|
47-63HZ
|
1030A
|
|
|
MODEL
NO. |
MAX OFF
STATE dv/dt |
MAX ON-STATE
VOLTAGE DROP |
ISOLATE
IMPEDENCE |
DIELECTRIC STRENGTH
INPUT-OUTPUT |
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE |
TURN ON
TIME |
TURN OFF
TIME |
CAPACITANCE
IN-OUT |
WEIGHT (g) |
K3PH20C25AA
|
250V/£gSEC
|
1.6Vrms
|
109 ohm
|
2500Vrms
|
2500Vrms
|
LESS1/2mSee
|
LESS1/2cycle
|
LESS473pf
|
600 g
|
K3PH20C40AA |
250V/£gSEC
|
1.6Vrms
|
109 ohm
|
2500Vrms
|
2500Vrms
|
LESS1/2mSee |
LESS1/2cycle |
LESS473pf
|
600 g
|
K3PH20C50AA |
250V/£gSEC
|
1.6Vrms
|
109 ohm
|
2500Vrms
|
2500Vrms
|
LESS1/2mSee |
LESS1/2cycle |
LESS473pf
|
600 g
|
K3PH20C75AA
|
250V/£gSEC
|
1.6Vrms
|
109 ohm
|
2500Vrms
|
2500Vrms
|
LESS1/2mSee
|
LESS1/2cycle
|
LESS473pf
|
600 g< | | |