SPECIFICATION
Feature Input/Output signal and Display Range are Selectable. No switching inaccuracy.
Accuracy? 0.1%RO at 23?3 .
Survey Scope 0.1Hz ~ 10KHz selectable.
Extra Power DC 12V , 30mA Maximun.
Display Range0.3" Super Red LED, 4-1/2 di
gits = 0?19999 Counts. Display range is changeable.
Adjustments Zero & Gain :Digital key formed adjustment, full range.
Protection
Without Damage for Input & Output Open or Short Circuit. Resist Surge, EMI, RFI.
Insulating Impedance100M/ DC 500V .
Setting Function Hi or Lo alarm type. Users can select freely. The LED of each terminal shines when it has action.
Setting Range0?19999 Counts. Ad
justable.
Deadband
justable.0 9999 Counts. Ad
Delay Time
justable.0 99 second. Ad
Relay Contact SPDT AC 120V 5A, 250V 3A, DC 24V 3A.
Dielectric Strength
AC 1600V / Min, between Input / Output / Power.
Analog Output LoadDC Current Mode500 at 20 mA;DC Volta
ge ModeDC 10mA Maximum.
Digital Output RS-485 Modbus-RTU, Buad Rate: 1200,2400,4800,9600,19200 selectable.
Linear and Linearity0.1%.
Common Mode Rejection120db DC to 60Hz.
Stability0.2% Drift Per Year.
Response Time 1 second.
Ripple(p-p) 0.1%rms RO.
Temperature Coefficient80ppm / From 060; 50ppm/25?5.
Operating Condition
–10 65 20 95% RH Non-Condensed.
Storage Condition
–20 75 20 95% RH Non-Condensed.
Power Supply AC 85~265V 45~70Hz ; DC 85~300V or DC 20~72V.
Housing Material ABS Plastic, Self-Extinguishing to UL Subject 94 Class V-O.
Case DIN rail or Wall.