3 Phase Power Analyzer / Power Meter
ReadyPlanet.com
dot
dot
Analog/Digital Timer SmartsTimer.com
aHot Product
Fan / Cooling Module
Flow
Gauge
Heater SmartsHeater.com
Inverter
Indicating lights
Level
Motor
Meter Smartsmeter.com
Process Controller SmartsController.com
PLC / HMI
Recorder/Datalogger/DAQ
Relay/SCR/Power Contron SmartsRelay.com
Sensor SmartsSensor.com
Switching Power Supply SmartsPower.com
Transducers / Transmitters / Converters SmartsTransmitter.com
Terminal Block / Connectors
Voltage/Supply Monitoring Relays
Water Pollution
Digicon
รวมร้านไฟฟ้า จำหน่ายอุปกรณ์ไฟฟ้าในพื้นที่
acim Product
dot
dot
dot
dot
There is person
dot

dot
dot
dot
Amount : 0 Items
Price : 0.00THB
bullet View cart
bullet Checkout
dot
Username :
Password :
Auto Log in :
bullet Lost Password
bullet Register
dot


smarts automation control instrument measurement


3 Phase Power Analyzer / Power Meter
View :   Sort :

Prev1Next
Found 11 items
KYORITSU KEW 6310 Power Quality Analyzer Power Meter
 view
Code : KYORITSU KEW 6310
KYORITSU KEW 6310 Power Quality Analyzer Power Meter
• Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured.
• 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis.
• One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory.
• Direct communication with PC via USB cable
• Built-in Input / Output Function of external signal enables the signal transmission to alarms.
• 2-way power supply by AC and Battery, and Nickel hydrogen battery usable with rechargeable function.
• Pull / Insert of CF card possible whenever on recording under the function of memory backup device.
• Can monitor insulation at leakage current by using optional leak clamp sensors.
• Built-in Print Screen Function enables to record display screen (Records 512 screens by using CF card: 1 screen 40KB).
• Can display Waveform and Vector, and can confirm the wiring connection, too.
• Complies fully with International Safety Standards
IEC 61010-1 CAT.III 600V.

Quantity :

KYORITSU 6300 Power Meter
 view
Code : KYORITSU 6300
KYORITSU 6300 Power Meter
• 12 kinds of power measurements
• Regenerative electric power can be measured
• Display 3 different data simultaneously on large screen.
• 4 types wiring system
• Recording internal can be set between 1 second and 1 hour
• Demand measurement
• Double power supply system AC line and Alkaline size AA battery LR6 : 6 pcs.
• Supplied with interface software for downloading data to PC via USB
• Direct communication with PC by USB connection
• The interface for compact flash card (CF card) is equipped.
• Back light function
• Designed to Safety Standard IEC 61010-1 CAT.III 600V.
Quantity :

KYORITSU KEW 6305 Compact Power Meter
 view
Code : KYORITSU KEW 6305
KYORITSU KEW 6305 Compact Power Meter
• Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems
• Voltage, Current, Power Factor and Frequency measurements
• Power analysis (Active, Apparent and Reactive power)
• Energy analysis (Active, Apparent and Reactive power)
• Active power accuracy: ±0.3%rdg±0.2%f.s.
• Automatic wiring check function to prevent incorrect connections
• Large memory capability (2GB) using built-in SD card interface
• Real time & remote measurements using Android application
• synchronous measurements between two units of KEW 6305
• Wide selection of clamp sensors allow measurements from 0.1A to 3000A
• The instrument automatically recognizes what kind of clamp sensor is connected to it
• Windows software for data analysis and setting via USB port or Bluetooth
Quantity :


 view
Code : PROVA-8500 Energy-Saving Teste
PROVA-8500 Energy-Saving Tester
* Standby power measurement ( 0 to 100W width 0.001W resolution)
* Regular power(0~2000W)
* 100W AC power supply + AC power analyzer]
* Programmable nominal output (85V to 250V , 45Hz to 65Hz)
* power quality measurement (W , PF , V , A)
* PC programmable through RS-232C interface( Optional RS-232C to USB bridge)
* Programmable Over current protection (OCP)
* Memory of 99 preset voltage and frequency
* Standby and Operation Button
* Back space for easy correction
*

Standby power measurement of note book, desktop PC, LCD TV,...


 view
Code : WM-01/02 Power Analyzer
WM-01/02 Power Analyzer
* 4 LCD Displays with W, PF, V, A
* Easy Plug-in and Test
* RS-232 Computer Interface


 view
Code : PROVA-6200 Graphic Power Quali
PROVA-6200 Graphic Power Quality Analyzer
* Analysis for Single Phase and Balanced 3 phase system
* True RMS Value(V and I)
* Active Power(K,KW,MW,GW)
* Apparent(VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
* Power Factor(PF),Phase Angle( Φ )
* Energy(WH,KWH,KVARH,PFH)
* Programmable PT(1 to 3000)Ratios
* Display of Overlapped Voltage and Current Waveform
* Maximum Demand (MD in W,KW,MW)with programmable Period
* Harmonic Analysis (V and I) to 50th Order
* Display of 25 Harmonics in one screen
* Optical Isolated RS-232C Interface
* Smart Datalogging to save Battery
* Datalogging of 32,64,128 or 256 points/cycles
* Analysis of Tatal Harmonic Distortion(%THD-F)
* Graphic Phasor Diagram
* Capture 128 Transient Events(Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD
* 50000 Records with Programmable Intervel (1 to 6000 seconds)
* Real-time Output of Wavaform,Power Parameters and Harmonics at Command
* Large Dot Matrix LCD Display with Backlight
* Power for Long-term Monitoring
* Built -in Calendar Clock for Data Logging


 view
Code : PROVA-19/21/23 Power and Harmo
PROVA-19/21/23 Power and Harmonics Analyzer
MODEL PROVA 19, 21, 23
* True RMS value (V and A)
* Leakage Current Measurement at 10 μ A Resolution
* Harmonic Analysis (V and A) to the 99 th Order
* Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
* Non-interrupted Harmonic Analysis
* Analysis of Total Harmonic Distortion (THD-F)
* Analysis of Crest Factor (C.F.)
* Fast Peak Function (33 μ s and 39 μ s)
* Programmable CT Ratio (1 to 250)
Model 21(50A) and 23(100A)
* W, KW, H.P.
* VA, KVA, VAR, KVAR
* PF, Phase Angle ( Φ )
* Energy (mWH, WH, KWH)
* Analysis of Standby Power Consumption
* Balanced 3 Φ Power Quality
* Balanced 3 Φ Sequence

TES-6830+6802 Power and Harmonics Analyzer (1000A)
 view
Code : TES-6830+6802 Power and Harmon
TES-6830+6802 Power and Harmonics Analyzer (1000A)
* Analysis for 3P4W, 3P3W, 1P2W, 1P3W
* True RMS Value (V 123 and L 123 )
* Active Power (W, KW, MW, GW)
* Apparent and Reactive Power (KVA, KVAR)
* Power Factor (PF), Phase Angle (Φ)
* Energy (WH, KWH, KVARH, PFH)
* Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
* Display of 35 Parameters in One Screen(3P4W)
* Programmable CT (1 to 600) and PT (1 to 3000) Ratios
* Display of Overlapped Voltage and Current Waveform
* 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
* Output of Waveform, Power Parameters and Harmonics at Command
* Large Dot Matrix LCD Display with Backlight
* Average Demand (AD in W, KW, MW)
* Maximum Demand (MD in W, KW, MW) with Programmable Period
* Harmonic Analysis to the 99th Order
* Display of 50 Harmonics in One Screen with Waveform
* Display of Waveform with Peak Values (1024 Samples/Period)
* Analysis of Total Harmonic Distortion (%THD-F)
* Graphic Phasor Diagram with 3 Phase System Parameters
* Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
* 3 Phase Voltage Unbalance Ratio (VUR)
* 3 Phase Voltage Unbalance Factor (d0%, d2%)
* Calculated Unbalance Current through Neutral Line (In)
* Optical isolated USB Interface
* Built-in Timer and Calendar for Data Logging
* Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
* 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
Quantity :


 view
Code : TES-6830+3007 Power and Harmon
TES-6830+3007 Power and Harmonics Analyzer ( 3000A)
* Analysis for 3P4W, 3P3W, 1P2W, 1P3W
* True RMS Value (V 123 and L 123 )
* Active Power (W, KW, MW, GW)
* Apparent and Reactive Power (KVA, KVAR)
* Power Factor (PF), Phase Angle (Φ)
* Energy (WH, KWH, KVARH, PFH)
* Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
* Display of 35 Parameters in One Screen(3P4W)
* Programmable CT (1 to 600) and PT (1 to 3000) Ratios
* Display of Overlapped Voltage and Current Waveform
* 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
* Output of Waveform, Power Parameters and Harmonics at Command
* Large Dot Matrix LCD Display with Backlight
* Average Demand (AD in W, KW, MW)
* Maximum Demand (MD in W, KW, MW) with Programmable Period
* Harmonic Analysis to the 99th Order
* Display of 50 Harmonics in One Screen with Waveform
* Display of Waveform with Peak Values (1024 Samples/Period)
* Analysis of Total Harmonic Distortion (%THD-F)
* Graphic Phasor Diagram with 3 Phase System Parameters
* Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
* 3 Phase Voltage Unbalance Ratio (VUR)
* 3 Phase Voltage Unbalance Factor (d0%, d2%)
* Calculated Unbalance Current through Neutral Line (In)
* Optical isolated USB Interface
* Built-in Timer and Calendar for Data Logging
* Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
* 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
Quantity :


 view
Code : TES-6830+6801 Power and Harmon
TES-6830+6801 Power and Harmonics Analyzer (100A)
* Analysis for 3P4W, 3P3W, 1P2W, 1P3W
* True RMS Value (V 123 and L 123 )
* Active Power (W, KW, MW, GW)
* Apparent and Reactive Power (KVA, KVAR)
* Power Factor (PF), Phase Angle (Φ)
* Energy (WH, KWH, KVARH, PFH)
* Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
* Display of 35 Parameters in One Screen(3P4W)
* Programmable CT (1 to 600) and PT (1 to 3000) Ratios
* Display of Overlapped Voltage and Current Waveform
* 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
* Output of Waveform, Power Parameters and Harmonics at Command
* Large Dot Matrix LCD Display with Backlight
* Average Demand (AD in W, KW, MW)
* Maximum Demand (MD in W, KW, MW) with Programmable Period
* Harmonic Analysis to the 99th Order
* Display of 50 Harmonics in One Screen with Waveform
* Display of Waveform with Peak Values (1024 Samples/Period)
* Analysis of Total Harmonic Distortion (%THD-F)
* Graphic Phasor Diagram with 3 Phase System Parameters
* Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
* 3 Phase Voltage Unbalance Ratio (VUR)
* 3 Phase Voltage Unbalance Factor (d0%, d2%)
* Calculated Unbalance Current through Neutral Line (In)
* Optical isolated USB Interface
* Built-in Timer and Calendar for Data Logging
* Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
* 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
Quantity :


 view
Code : TES-3600 3P4W
TES Power Analyzer Meter TES3600 3P4W
* 10 Display Easy - to - View LCD Screen.
* Connectors for 4 Current Sensing Clamps.
* 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
* True RMS Sensing.
* Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
* Phase sequency indicator function.
* Backlight display function.
* Manual Data Memory and Read (99 sets).
* Data Logging (512KB Memory, 20,000 sets)
* Programmable Trigger - Points and Start / Stop Time.
* RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
* Easy - to - use Push - Button Operation.
* Light Weight, Portable Design.


Prev1Next