Temperature Control เครื่องควบคุมอุณหภูมิ Micro Computer Temperature Controller เครื่องควบคุมอุณหภูมิ
 |
approval & free power |
All models get CE and UL approval. |
Operate on any voltage from AC
85~265V at 50/60Hz. |
DC 24V is also available (optional
function) |
|
 |
IP66(NEMA4) dust & water proof is available for all models(optional
function)
|
|
|
|
Heater current flowing through CT can be displayed on controller
If heater current is less than HBA set value. AL1will be activated(optional
function) |
|
 |
FY series suport both MODBUS RTU and MODBUS ASCII protocal.
Communication between controller and HMIa or other equipment is more conveniet(optional function)
|
|
 |
AT Function can calculate the
optimize PID value for your control system,without trying and error
manually.
|
|
|
 |
Conveniently switched between auto
/manual output mode by clicking
"A/M" key(except"FY400"). |
|
 |
Real time monitor the status of
output (OUT1/OUT2), AT, alarm
(AL1/AL2/AL3), manual output(MAN) and program(PRO) |
|
|
 |
Output percent displayed on the bar-graph in 10 LEDs resolution
(except"FY400").
|
|
Input with 14bit A/D resolution, 0.2% accuracy of FS. Built in "AutoZero-
AutoSpan" function keep good
accuracy.
|
|
Built in 1 segment of RAMP & SOAK function.
Applicable on "SOFT" start condition.
|
|
Continuous checks the input status, RAM status and A/D status. When error was detected, the
corresponding error code will be
displayed on controller so that user can identify the source of trouble
easily. |
|
All parameters are seperated in 3 operation levels. Each parameter can be hidden or locked to prevent
unauthorized changes.
|
|
 |
PLC |
 |
Another controller |
 |
|
|
 |
 |
Input type :
0~20mA,4~20mA
0~5V,0~10V,2~10V,0~1V |
|
|
 |
|
Recorder |
 |
Display |
 |
|
 |
Signal type :PV,SV
Output type:
0~20mA,4~20mA
0~5V,0~10V,2~10V,0~1V |
|
|
|
|
(RS485 Communication) |
|
|
|
Up to 31 controllers
can be connected
Max length 1200M |
|
|
Up to 10 controllers can be connected Max length 1M |
 |
The SV vaiue of siave controllers will be remoted by master controller, and
reached to max value at the same time |
|
 |
 |
There are 2 patterns by 8 segments can be used in ramp/soak program |
 |
There are 2 patterns can be linked togetter as 16 segments i ramp/soak program. |
|
Heationg and Cooling Control |
|
|
|
|
 |
■ Control Method |
■ Fuzzy |
 |
■ Autotuning(AT) |
■ Limit Setting |
 |
 |
■ Easy Mounting |
■ Saving Space |
 |
|
|
|
TAIE single-loop controller introduction |
FY |
series digital controllers are single-loop PID controllers, which are suitable for various industrial process controls. Temperature control is one of the main applications.
|
PFY |
series added the “SV RAMP/SOAK programmable” function to FY series, all other functions are the same with FY series.
|
|
There are 16 segments of RAMP/SOAK in 2 patterns for programming.
|
 |
 |
4-digits 8888 LED 7-segment display |
The upper display is PV (process value) , and the lower display is SV (set value) display. Input accuracy is ±0.2%
|
Input sampling time is 250ms Build in Auto-Tuning(AT) function can be used to get optimize PID value automatically.
|
|
Board type Digital PID controller |
External interface unit -
|
It allows set and monitor all parameters by key operation manually.
|
External display unit -
|
For PV/SV monitoring, prevent unauthorized operation with controller.
|
Fixed and Plug In wiring terminals type -
|
It is suitable for different wiring method.
|
|
General spec introduction |
FY/PFY controller can accept various process input, like temperature, humidity, pressure, flow, PH, and various analog linear inputs, like DC 4~20mA, 0~20mA, 0~5V, 0~10V etc.
|
Temperature control : Available for TC, RTD, Linear(mA / V/mV) sensor input. |
|
TC types can be chosen by front panel key operation. DPT/JPT types can be chosen by front panel key operation. |
|
TC |
Thermal couple |
K . J . R . S . B . E . N . T . W . U . L . PL2 |
|
RTD |
Resistance Temperature Device |
DIN PT100 / JIS PT100 |
|
AN |
Linear DC Input |
V . mV . mA |
Dimension (option) |
|
FY100 |
175 x 110 mm |
Board |
|
FY400 |
48 x 48 mm |
DIN 1/16 |
|
FY600 |
96 x 48 mm |
DIN 1/8 |
|
FY700 |
72 x 72 mm |
DIN 3/16 |
|
FY800 |
48 x 96 mm |
DIN 1/8 |
|
FY900 |
96 x 96 mm |
DIN 1/4 |
Function description Refer to “ Order Information” |
|
Programmable function : |
|
2 sets; each set has 8-section programmable control available. (Option) |
|
Control output function : |
Available for 2 sets of control output (HEAT/COOL control)
The standard control output types include Relay, SSR Drive, Linear Output (mA,V).
OUT1 can be used as HEAT control (reverse action ) or COOL control (direct action).
OUT1 + OUT2 is suitable for HEAT/COOL control.
Advanced control output include “Three wire motor valve control (Optional).
SCR/TRIC Trigger (Optional).
|
|
Control Algorithm : |
|
PID and FUZZY control modes are available through operation board for compatible of different loading. |
|
Alarm output : |
|
Maximum with 3 sets of Alarm output
Totally 17 types of alarm modes for selection.
is also available for heater break detection.
1 unit of CT (Current Transformer) is included in this option.
|
|
Heater break alarm (HBA) : |
|
Heater current through CT can be displayed on controller.
Using this function to inspect HEATER current and protect HEATER in advance.
|
|
Transmission (TRS) output function (Optional) :
|
|
TRS output value is correspond to PV or SV display value
Various output type for selection include DC 4~20mA, 0~20mA, 0~5V, 0~10V,1~5V, 2~10V.
It can be used with external temperature recorder or external large display
|
|
Remote SV function (Optional): |
|
SV in FY controller can be remote by external analog signal from PLC or other controllers
|
|
RS232/RS485 communication function (Optional) : |
|
FY controllers support “Modbus” communication protocol.
It’s easy for using FY controllers to communicate with various HMI and PLC.
RS232 or RS485 communication interface are available by custom selection.
Up to 32 controllers can be connected together in RS485 communication and max wiring length is 1200m.
|
|
TTL communication function (Optional): |
|
Up to 10 controllers can be linked together in TTL communication network.
The SV of slave controllers will be remote by master controller and reached to max value at the same time.
|
|
Water/ Dust proof function (Optional): |
|
Front panel conformed to IP65 Water/Dust proof level. This function had been tested and authorized by third country’s laboratory.
|
|
PV Offset function : |
|
The PV offset value can be adjusted by manual setting.
|
|
Digital PV Filter function : |
|
It can be applied to adjust PV display time to prevent PV changed rapidly due to external noise.
|
|
Data Lock function: |
|
All parameters are separated in 3 operation levels.
Each parameter can be hidden or locked to prevent unauthorized changes.
|
|
Other functions: |
|
|
Output mode can be switched between AUTO and MANUAL mode by front key operation .It is useful for output simulation. |
|
|
Output percentages displayed on the bar-graph in 10 LED’s resolution. |
|
|
Data storage in a high reliability EEPROM . |
|
|
Self-diagnosis function continuously monitors controller internal status and displays corresponding error codes if error status is occurred. |
|
|
Auto-Zero and Auto-Span function keep good accuracy for long-term use. |
|
|
Universal power range (AC85~265V , 50/60HZ) .Thus FY controller can be applied in any country around the world |
|
|
DC24V power is also available (Optional). |
|
|
|
|
 |
Model |
FY400 |
FY600 |
FY700 |
FY800 |
FY900 |
Dimension |
48×48mm |
96×48mm |
72×72mm |
48×96mm |
96×96mm |
Supply voltage |
AC 85~265V, DC24V(Optional) |
Frequency |
50/60HZ |
Power Consumption |
approx 3VA |
approx 4VA |
approx 3VA |
approx 4VA |
approx 4VA |
Memory |
Non-volatile memory E2PROM |
Input |
Measurement input,Sample time : 250ms |
TC |
K, J, R, S, B, E, N, T, W5Re/W26Re, PL2, U, L |
RTD |
PT100, JPT100, JPT50 |
mA dc |
4~20mA, 0~20mA |
Voltage dc |
0~1V, 0~5V, 0~10V, 1~5V, 2~10V,
-10~10mV, 0~10mV, 0~20mV, 0~50mV,10~50mV |
DP Position |
0000, 000.0, 00.00 0.000(available for mA or Voltage dc input) |
Output 1 |
Main control output |
Relay |
SPST type |
SPDT type |
SPDT type |
SPDT type |
SPDT type |
3A, 220V,electrical life:100,000 times or more(under the rated load)。 |
Voltage Pulse |
For SSR drive。ON:20mA。Maximum load current:20mA. |
mA dc |
4~20mA, 0~20mA。Maximum load resistance:560Ω. |
Voltage dc |
0~5V, 0~10V, 1~5V, 2~10V。Maximum load current:20mA |
Alarm 1 |
SPST type |
SPST type |
SPST type |
SPDT type |
SPDT type |
3A, 220V,electrical life:100,000times or more(under the rated load) |
Control algorithms |
PID,P, PI, PD, ON/OFF(P=0), FUZZY |
PID range |
P:0~200%, I:0~3600 Secs, D:0~900 Secs |
Accuracy |
0.2% of FS |
Isolation |
Output terminal (control output,alarm,transmission) and input
terminal are isolated separately |
Isolated resistance |
10M Ω or more between input terminals and case(ground) at DC 500V
10M Ω or more between output terminals and case(ground) at DC 500V |
Dielectric strength |
1000V AC for 1 minute between input terminals and case(ground)
1500V AC for 1 minute between output terminals and case(ground) |
Operating temperature |
0~65℃ / 0~50 ℃ |
Humidity range |
20~90% RH |
Weight |
FY400 approx 150g,FY600 / 700 / 800 approx 225g,
FY900 approx 300g |
Display Height |
PV:7mm
SV:7mm |
PV:7mm
SV:7mm |
PV:14mm
SV:10mm |
PV:7mm
SV:7mm |
PV:14mm
SV:10mm |
|
|
|
Model |
FY400 |
FY600 |
FY700 |
FY800 |
FY900 |
Output 2 |
For heating and cooling control use.
Relay,SSR,4~20mA,0~20mA ,0~5V,0~10V,1~5V, 2~10V |
Output 2 |
SPST type |
SPST type |
SPST type |
SPST type |
SPST type |
3A , 220V , electrical life:100,000 times or more(under rated
load) |
Alarm 3 |
Not availble |
available |
available |
available |
available |
SPST type |
SPST type |
SPST type |
SPST type |
3A , 220V , electrical life: 100,000 times or more(under rated load) |
Heater Break Alarm
(HBA) |
Display range of heater current:0.0~99.9A, Accuracy : 1%FS |
Included CT:SC-80-T(5.8 mm dia,0.0~80.0A)
or SC-100-T(12 mm dia,0.0~99.9A) |
Alarm relay : AL1 |
Transmission |
Available for PV or SV transmission |
4~20mA , 0~20mA , 0~1V , 0~5V , 0~10V , 1~5V , 2~10V |
Remote SV
|
4~20mA , 0~20mA , 0~1V , 0~5V , 0~10V , 1~5V , 2~10V |
Communication |
Protocol: MODBUS RTU , MDOBUS ASCII , TAIE |
RS232 , RS485 ,TTL |
Baud rate: 2400 , 4800 , 9600 , 19200 , 38400 bps |
Data bits: 8bit , Stop bit:1 or 2bit, Odd or Even parity |
Water/Dust proof |
IP65 |
 |
|
Model |
FY400 |
FY600 |
FY700 |
FY800 |
FY900 |
1φ zero crossing
control (1φSSR) |
Available |
Not available |
Available |
Not available |
Available |
3φ zero crossing
control (3φSSR) |
Available |
Available |
Motor valve control |
Available |
1φ phase angle control (1φSSR) |
Not a vailable |
Available |
3φ phase angle control
(3φSSR) |
Not a vailable |
Available |
Model |
PFY400 |
PFY600 |
PFY700 |
PFY800 |
PFY900 |
Programmable
RAMP/SOAK |
2 patterns with 8 segments each.
The 2 patterns can be linked together as 16 segments use. |
|
|
|
FY400

FY800

|
FY600

FY700 / FY900

|
SYMBOL |
NAME |
FUNCTION |
PV |
① |
Measured value (PV) display |
Displays PV or various parameter symbols(Red) |
SV |
② |
Setting value(SV)display |
Displays SV or various parameter values(Green) |
SET |
③ |
Set key |
Used for parameter calling up and
set value registration |
A/M |
④ |
Auto/manual key |
Switches between Auto(PID)
output mode and Manual output |
< |
⑤ |
Shift Key |
Shift digits when settings are changed |
∨ |
⑥ |
Donw Key
(*Program Hold) |
Decrease numbers
(*Only for programmable controller) |
∧ |
⑦ |
Up Key
(*Program Run) |
Increase numbers
(*Only for programmable controller) |
SYMBOL |
NAME |
FUNCTION |
OUT1 |
⑧ |
OUT1 lamp |
Lights when OUT1 is on(Green) |
OUT2 |
⑨ |
OUT2 lamp |
Lights when OUT2 is on (Green) |
AT |
⑩ |
Autotuning lamp |
Lights when Autotuning is activated (Orange) |
AL1 |
⑾ |
Alarm1 lamp |
Lights when Alarm 1 is activated(Red) |
AL2 |
⑿ |
Alarm2 lamp |
Lights when Alarm 2 is activated(Red) |
AL3 |
⒀ |
Alarm3 lamp |
Lights when Alarm 3 is activated(Red) |
MAN |
⒁ |
Manual output lamp |
Lights when manual output is activated(Orange) |
PRO |
⒂ |
*Program Running lamp |
*Flashes when program running
(Only for programmable controller) |
OUT1% |
⒃ |
Output % Bar Graph display |
Output % is displayed on 10-dot LEDs
|
|
|
|
■ FY400 |
 |
|
■ FY600 |
 |
|
■ FY700 |
 |
|
■ FY800 |
 |
|
■ FY900 |
 |
|
■ FY100 |

|
|
|
|
■ FY400 |
■ FY700 |
 |
 |
|
■ FY600 / 800 |
■ FY900 |
 |
 |
|
|
|
|
|
Application Industry
|

|
Plastic, rubber, equipment |
1.
|
Injection molding machinery |
2.
|
Extruding machinery |
3.
|
Mold temperature controllers |
4.
|
Vacuum forming, |
5.
|
Pneumatic forming, |
6.
|
Foaming machinery |
7.
|
Blow molding (Thermofoaming) |
8.
|
Rubber press |
9.
|
Film extruder (calender roll) |
|
Electric furnaces |
1.
|
Tunnel furnace |
2.
|
Reflow furnace |
3.
|
Vacuum furnace |
4.
|
Baking furnace |
5.
|
Kiln furnace |
6.
|
Diffusion furnace |
7.
|
Heavy oil, gas furnaces |
8.
|
Aluminum, tin, lead, zinc melting furnace |
9.
|
Incinerator |
10. |
Metal heat treating |
|
Semiconductor electronic
components industry |
1.
|
Bonding machine |
2.
|
Mold equipment |
3.
|
Preheater |
4.
|
Cleaning equipment |
5.
|
Photo resist coating |
6.
|
Diffusion equipment |
7.
|
TFT liquid crystal manufacturina
eauioment |
|
Packing machine industry |
1.
|
Bag-making machinery |
2.
|
Filling packing machinery |
3.
|
Sealing machinery |
4.
|
Shrinking packing machinery |
5.
|
Hot blast sealina |
|
Food related industry |
1.
|
Bakery, confectionery equipment |
2.
|
Cooking appliances |
3.
|
Refrigerating machine (General, for fishing vessel) |
4.
|
Humidifier |
5.
|
Dryer |
6.
|
Brewing machine (Liquor, soy sauce, Miso) |
7.
|
Tobacco drver |
|
Pottery manufacturing Ceramic
and Glass industry |
1.
|
Flame resistant bricks |
2.
|
Ceramic industry |
3.
|
Concrete, Asphalt, Cement industries |
4.
|
Glass industry |
5.
|
Porcelain enameling |
6.
|
Grind stone manufacturing |
|
Textile machinery |
1.
|
Dyeing machinery |
2.
|
Dryer |
3.
|
Heater |
4.
|
Thread plying |
5.
|
Vinyl, synthetic leather |
|
Others |
1.
|
Constant temperature oven |
2.
|
Air conditioners (for cooling and heating) |
3.
|
Bath and pool |
|
|
|
|
|